小说区图片区偷拍区另类_日韩中文字幕在线一区二区三区_久久精品亚洲欧美日韩_99久久久国产精品免费_国产精品久久久久久超碰

咨詢熱線

15021885022

當(dāng)前位置:首頁(yè)  >  技術(shù)文章  >  YD-3000在線水質(zhì)硬度計(jì)說明書

YD-3000在線水質(zhì)硬度計(jì)說明書

更新時(shí)間:2018-02-28      點(diǎn)擊次數(shù):2521

YD-3000在線水質(zhì)硬度計(jì)說明書

 

一、規(guī)格

............................................................................................................

01

二、安全與注意事項(xiàng) ..........................................................................................

02

三、組合與安裝....................................................................................................

02

3.1 安裝

 

3.1.1

盤面式安裝參考圖...............................................................................................

02

3.1.1

儀器盤裝式、管裝式及壁掛式安裝..................................................................

02

3.2 背板接線說明

 

3.2.1

背板接線圖...........................................................................................................

03

3.2.2 背板接點(diǎn)說明........................................................................................................

03

3.3 電極接線說明

 

3.3.1

電極配線參考圖...................................................................................................

04

3.3.2

電極纜線開線方法...............................................................................................

04

四、面板介紹........................................................................................................

05

4.1

前面板及按鍵說明....................................................................................................

05

4.2

顯示幕說明................................................................................................................

05

五、參數(shù)設(shè)定.......................................................................................................

06

5.1

進(jìn)入?yún)?shù)設(shè)定模式....................................................................................................

06

5.2

測(cè)量參數(shù)選擇...........................................................................................................

06

5.3

溫度參數(shù)選擇...........................................................................................................

07

5.4

電流輸出(一)參數(shù)設(shè)定......................................................................................

08

5.5

電流輸出(二)參數(shù)設(shè)定......................................................................................

09

5.6

高點(diǎn) REL1 繼電器參數(shù)設(shè)定...................................................................................

10

5.7

低點(diǎn) REL2 繼電器參數(shù)設(shè)定...................................................................................

11

5.8

清洗繼電器參數(shù)設(shè)定...............................................................................................

12

5.9

數(shù)字濾波參數(shù)設(shè)定...................................................................................................

13

5.10 顯示參數(shù)設(shè)定.........................................................................................................

13

5.11 密碼參數(shù)設(shè)定.........................................................................................................

14

六、校正

..............................................................................................................

15

6.1

進(jìn)入校正模式...........................................................................................................

15

6.2

校正流程圖...............................................................................................................

15

6.3

離子類型設(shè)定...........................................................................................................

17

6.4

校正信息查看...........................................................................................................

17

6.5

密碼參數(shù)設(shè)定.............................................................................................................

18

七、錯(cuò)誤訊息........................................................................................................

19

八、保養(yǎng)

...............................................................................................................

19

測(cè)試項(xiàng)目

 

ION/ORP/TEMP

 

 

 

 

 

 

 

 

測(cè)

 

 

 

ION

0.00~20000 (ppm/mg/L)

[X--/X-/X+/X++]

 

 

 

 

 

 

 

 

 

 

 

ORP

-2000.0~2000.0mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP

-30.0~130.0°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ION

0.01/0.1/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORP

0.1mV

 

 

 

 

 

 

 

 

 

 

 

TEMP

0.1°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ION

±10%(依傳感器而定)

 

 

 

 

 

±0.06%

 

 

 

 

ORP

 

 

 

 

 

 

 

 

 

 

 

 

TEMP

±0.2°C

 

 

 

 

 

 

 

溫度補(bǔ)償

 

NTC30K/ PT1000/手動(dòng)溫度補(bǔ)償模式;自動(dòng)識(shí)別溫度傳感器

 

 

 

 

 

 

 

各溫度模式下均可作溫度修正或設(shè)定

 

 

 

 

 

 

 

 

 

 

 

 

校正模式

 

兩點(diǎn)或三點(diǎn)校正(提供 13 個(gè)區(qū)段可選擇)

 

 

 

 

 

 

工作環(huán)境溫度

0~50°C

 

 

 

 

 

 

 

儲(chǔ)存環(huán)境溫度

-20~70°C

 

 

 

 

 

 

 

 

輸入阻抗

 

> 1012 Ω

 

顯示螢?zāi)?/span>

 

液晶顯示,可 AUTO/ON/OFF 背光

 

 

 

 

 

電流輸出一

隔離式 4~20mA 對(duì)應(yīng) ION/TEMP 量測(cè)范圍,zui大負(fù)載 500W

 

 

 

 

 

電流輸出二

隔離式 4~20mA 對(duì)應(yīng) ION/TEMP 量測(cè)范圍,zui大負(fù)載 500W

 

 

 

 

 

數(shù)字通訊接口

選配 MODBUS 協(xié)議

 

 

 

 

 

 

 

 

接點(diǎn)輸出

RELAY ON/OFF 接點(diǎn),240VAC 0. Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

設(shè)定

兩組獨(dú)立設(shè)定之 HI/LO 控制點(diǎn),帶滯后設(shè)定

 

 

 

 

 

 

 

 

 

 

 

清洗設(shè)定

 

ON 0~9999 秒/OFF 0~999.9 小時(shí)

 

 

 

 

 

 

 

保護(hù)等級(jí)

 

IP65

 

 

 

 

 

 

 

 

電源供應(yīng)

 

100V~240VAC±10%,50/60Hz

 

20V~40VDC, Imax.=0.

 

 

 

 

 

 

安裝方式

 

壁掛式/管路式/盤面式

 

 

 

 

 

 

本機(jī)尺寸

 

96 mm ´ 96 mm ´ 148mm (H´W´D)

 

 

 

 

 

 

挖孔尺寸

 

92 mm ´ 92 mm (H´W)

 

 

 

 

 

 

 

 

 

重量

 

0.4Kg

 

注意:

  • ppm 或 mg/l 均為濃度單位,其校正方式均相同。

 

  • 本機(jī)共提供兩種校正方式 CC 及 CA,各校正方式均提供有 13 個(gè)區(qū)段可選擇。1.00、2.00、5.00、10.00、20.00、50.00、100.0、200.0、500、1000、2000、5000、10000。
  • CC 可做兩點(diǎn)或三點(diǎn)校正,作三點(diǎn)校正時(shí)必須依照順序,由高而低或由低而高均可。

 

  • 當(dāng)多點(diǎn)校正后,放入樣品中測(cè)量,如測(cè)量時(shí)發(fā)現(xiàn)實(shí)際值與測(cè)量值有差異,則可采用單點(diǎn)修正。
上海博取儀器有限公司
  • 聯(lián)系人:邢銀鳳
  • 地址:上海浦東新區(qū)秀沿路118號(hào)
  • 郵箱:2355456200@qq.com
  • 手機(jī):15021885022
關(guān)注我們

歡迎您關(guān)注我們的微信公眾號(hào)了解更多信息

掃一掃
關(guān)注我們
版權(quán)所有©2024上海博取儀器有限公司All Rights Reserved    備案號(hào):滬ICP備08017338號(hào)-29    sitemap.xml    總訪問量:615098
管理登陸    技術(shù)支持:儀表網(wǎng)